Dell poweredge r420 btu. Average Polling Period - 4 AC Cycles Variable Speed Fan Control Based on Power or Thermal Readings Yes. Dell poweredge r420 btu

 
 Average Polling Period - 4 AC Cycles Variable Speed Fan Control Based on Power or Thermal Readings YesDell poweredge r420 btu  Enter Details

Do not turn off your computer or disconnect from the power source while updating the BIOS as this could harm your computer. #1 Best Seller. Drivers & Downloads. A 2-socket, 1U rack server, the Dell PowerEdge R420 delivers mainstream performance and density. Rack rail specifications Table 28 lists the spacing dimensions for the. The iDRAC is a piece of hardware that sits on the server motherboard that allows Systems Administrators to update and manage Dell systems, even when the server is turned off. The iDRAC also provides both a web interface and command line interface that allows administrators to perform remote management tasks. To use it, download the file and copy it to a DOS-bootable USB flash drive, then boot the system to the. 00. Price: $150. Even after removing the PCIe card and resetting the. PowerEdge R420. Dell Official Site: Shop the latest Dell computers, electronics & technology solutions. About Your System. everything else, down to the option in bios are identical. Format Description: This file format consists of a BIOS-executable file. 10GHz 8 Core CPUs . 17 MB. Dell Sites. It supports a maximum of two Xeon processors, up to 384GB of memory, and up to 16TB of storage. Complete The Operating System Setup. The Dell Services team takes a holistic view of your needs and designs solutions for your environment and business objectives while leveraging proven delivery methods, local talent, and in-depth domain knowledge for the lowest TCO. Diagnostic Indicators. Hope this helps. Choose the document format by clicking on the PDF or HTML link behind the Owner's Manual / User Manual entry or, if given, the Technical Specifications. To use it, download the file and copy it to a DOS-bootable USB flash drive, then boot the system to the USB flash drive and run the program. A two-socket, 1u rack server (2 pages) Server Dell PowerEdge R420xr Getting Started Manual. A 2-socket, 1U rack server, the Dell PowerEdge R420 delivers mainstream performance and density. PowerEdge R420XR. その他の情報. DELL POWER EDGE R410. ENERGY STAR Power and Performance Data Sheet. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells youwe are facing a severe heating issue on top of the chassis above the raid card with all these 6 servers. Install Microsoft Windows 2012 R2. For more information. Consulting and deployment offerings are also available. Overview. 5”), and an exceptional value. 1u server 128gb ram. システムの電源投入. 73. • PowerEdge R420 • PowerEdge M830 • DCS 6400 • PowerEdge R520 • PowerEdge R230 • DCSF S3500 • PowerEdge R620 • PowerEdge R330 • DSS 1500 • PowerEdge R720 • PowerEdge R430 • DSS 1510. So, i recently bought a Dell PowerEdge R420. PowerEdge R420. 5" Caddies (with screws) Controller H710 Dell H710 1GB RAID Controller. Density and performanceGet an energy-efficient, dense 1U server for your applications with the PowerEdge™ R420, featuring next-generation processing and flexible I/O options. 1356 BTU/hr maximum. The Dell PowerEdge R430 is designed to deliver peak 2-socket performance in a compact package. Dell PowerEdge R420 Getting Started Guide Regulatory Model: E18S Series Regulatory Type: E18S001. The lifecycle controller needs to be at least on 2. 5-inch hot-swap drives. There is not a configuration option to have a second integrated NIC. Storage. Does the server work without raid controller i mean the storageHow to remove RAM on a PowerEdge R420. Dell Outlet Business & Education. 5” or 2. A 2-socket, 1U rack server, the Dell PowerEdge R420 delivers mainstream performance and density. A 2-socket, 1U rack server, the Dell PowerEdge R420 delivers mainstream performance and density. 5in HDDs. 55. This service is temporarily unavailable. which one should be considered? And should I be doubling the value for the entire server as it's having dual power supplies?Perform the following procedures to install and use the PERCCLI in Linux operating systems: Download the Linux PERCCLI utility from Dell support site. 1356 BTU/h como máximo (suministro de energía de 350 W, redundante) 2132 BTU/h como máximo (suministro de energía. Minimum Typical Maximum. How to Setup and Manage Your iDRAC or CMC for Dell PowerEdge Servers and Blades; Export a SupportAssist Collection over iDRAC7. Back panel features. Enable V4 DHCP (assuming that was current setting). 02 MB. Rails allow for the most efficient use of space when mounting servers. The drives are visible in System BIOS. Refurbished. Folks, I currently have a Dell PowerEdge R420 server running VMware ESXi 5. Installing The Optional Bezel. Hard-Drive Indicator Patterns. 5. Dell PowerEdge R420 This model server has a 1U form factor, two processor sockets, and uses Intel Xeon E5-2400 series processors. # cfgServerPowerLastHourAvg=-1377 AC W | -4699 Btu/hr # cfgServerPowerLastDayAvg=-1406 AC W | -4798 Btu/hr # cfgServerPowerLastWeekAvg=-1406 AC W | -4798 Btu/hr # cfgServerPowerLastHourMinPower=1054 AC W | 3597 Btu/hr # cfgServerPowerLastHourMinTime=Mon Jan 11 19:29:04 2021 # cfgServerPowerLastHourMaxPower=64762 AC W | 221033 Btu/hr Installation And Configuration. Power AC Power Supply (per power supply) Wattage 495 W, 750 W, or 1100 W Heat dissipation NOTE: Heat dissipation is calculated using the power supply wattage rating. 19-01-2021 22:00 PM. It can address up to 384GB (32GB X 12) of DDR3. 8” SATA SSD Up to 10 x 2. 00. 73. Documentation. Download. To use it, download the file and copy it to a DOS-bootable USB flash drive, then boot the system to the USB flash drive and run the program. exe. 356 BTU/jam (redundan, catu daya 350 W) Maksimal 2. Related Articles . Be the first to write a review. The PowerEdge R410 features include an available “open”The R730 and R730xd support new Dell PowerEdge RAID Controller (PERC) cards with improved functionality and faster performance. Front-Panel Features And Indicators. 3. I tried to click everything in. Available for PCs, PowerEdge servers,. Dell PowerEdge R420 Getting Started Guide Publish date: 15 DEC 2014. dell poweredge r630 server. 4-bay chassis with either hot-swap or cabled 3. Drivers & Downloads. Key technologies New technology Detailed description New Intel processors The new Intel Xeon processor E5-2400 and E5-2400 v2 product families, the Intel Xeon E5- 1410 processor, and the Intel Pentiumprocessor 1400 product family offer features such as. 12 DIMMs. com. PowerEdge R450. El procedimiento para actualizar BIOS e iDRAC, es el siguiente (asumiendo que tiene Windows Server instalado, si no es así, dígamelo y le facilito una alternativa): Primero descargue las actualizaciones de BIOS e iDRAC. However, we do have the option to change the thermal settings starting from 12G (PE R420) But it is not recommended to lower fan speed. Overview. A powerful, 2-socket rack server, the PowerEdge R520 delivers balanced performance and storage expandability for data-intensive applications. For more information, see Dell KB article Dell PowerEdge: Update the firmware of Single System Components Remotely Using the iDRAC. 16-12-2017 07:00 AM. A 2-socket, 1U rack server, the Dell PowerEdge R420 delivers mainstream performance and density. The Dell PowerEdge R420 is a two-socket 1U rack server that delivers an intuitive, user-friendly experience, coupled with robust technical capabilities that make it an excellent choice for any small business looking for a network solution. This service is temporarily unavailable. However, I can't get the drive to power up. File Size: 3. Extremely affordable, the R420. I plan to change the non-redundant for two 550W redundant power supply units. Type c:, and press . This is obviously not an issue due to the 4 bay restriction of the R420, but good to keep in mind. Then for the following storage devices. Documentation. how to enable fingerprint log in Dell 5370 laptop in ubuntu 18. For replacement system board you can check Sticker by DIMM slots for CPU2 for your DP/N number. It may only occupy a 1u space but it's densely packed and well-engineered. It did NOT help, the reset was done, but the option to enable / disable the embedded video controller is still highlighted in gray. 2132 BTU/h como máximo (suministro de energía de 550 W,. MD1000 430w 1467. Note: Update Packages for Linux are open source. setup > bios setup > there is no menu point „network setup/settings„ But this menu does not exist. Servers, Storage, & Networking-> PowerEdge-> PowerEdge R740). Cable routing procedures (11 pages) Server Dell PowerEdge R420 Installation Manual. When changing back to BIOS mode via the bios settings, it confirms that it saved, but when rebooting it stays on UEFI mode. OMPC also provides features for Power and cooling analysis. Enter Details. Overview. Service Events. They works correctly, but I want to max it. Documentation. 5 A–3 A 750 W AC Platinum 2891 BTU/hr 50/60 Hz 100–240 V AC, autoranging# cfgServerPowerLastHourAvg=-1377 AC W | -4699 Btu/hr # cfgServerPowerLastDayAvg=-1406 AC W | -4798 Btu/hr # cfgServerPowerLastWeekAvg=-1406 AC W | -4798 Btu/hr # cfgServerPowerLastHourMinPower=1054 AC W | 3597 Btu/hr # cfgServerPowerLastHourMinTime=Mon Jan 11 19:29:04 2021 #. ) If a restart is triggered, either by the user or Windows Update, the server seems to shut down instead, which is a major problem for a remote data center machine. PowerEdge R520. ベゼル(オプション)の取り付け. Hi, In iDRAC Web interface, go to Configuration > Power Management > Power Configuration. 0GHz Six Core 15M Processor. PowerEdge 2950 306w 1044. Dell PowerEdge R420 Fixed Rails 最大为 1356 btu/小时(冗余,350 w 电源设备) 最大为 2132 btu/小时(冗余,550 w 电源设备) 最大为 2315 btu/小时(非冗余,550 w 电源设备) 电压 注: 此系统也设计为连接到相间电压不 超过 230 v 的 it 电源系统。 100–240 v 交流、自动调节范围、50/60 hz 电池 7 Dell PowerEdge R220 Technical Guide New technology Detailed description iDRAC7 with LifeCycle Controller The new embedded system management solution for Dell PowerEdge servers features hardware and firmware inventory and alerting, in depth memory alerting, faster performance, dedicated gigabit port, email alerts, electronic licensing, 2021 Dell Inc. Pyle 19-Inch 1U Server, Vented Shelves for Good Air Circulation Cantilever Wall Rack. Press the release button to open the hard-drive carrier release handle. The Dell PowerEdge R420 is a two-socket 1U rack server that delivers an intuitive, user-friendly experience, coupled with robust technical capabilities that make it an excellent choice for any small business looking for a network solution. R420 nic speed for Intel ethernet 10G x520 adapters. Below are system board part numbers. 00The official description of DELL PowerEdge R420 server Rack (1U) Intel® Xeon® E5 Family E5-2420 1. Enter your Service Tag. 2 MB. maintaining your Dell PowerEdge servers. A RAID controller is a hardware device on high-end servers or software program on low-end servers that are used to. Windows and Firmware is. I own currently a second-hand Poweredge R420, with a non-redundant 550W power supply, 2 processors and 64 GB of memory. US/EN. 68” (42. 2 days ago I upgraded its RAM, and according to my monitoring (Zabbix running in a VM inside this server) it has rebooted 3x since that. Note that your array should all be SAS drives. Created Date:PowerEdge R420. PowerEdge R420. 0:22. Power Indicator Codes. Overview. Second processor installation–information update (8 pages) Server Dell Precision R5500 Setup & Features Manual. How to replace Raid Card for PowerEdge R420. 1. Dell PowerEdge R420 Systems Owner's Manual. Chassis dimensions. Documentation. Connecting The Power Cable (s) Securing The Power Cable (s) Turning On The System. Monitor Deals. Form Factor 1U rackmount. Hardware PE R420 with single CPU, enough RAM, RAID 1 with hotspare, Perc 310, Windows 2012 R2 with Hyper V enabled. $134. exe. Hard Drives: 4x Enterprise. current listing of the specifications for your system, go to support. Enter the Service Tag of your PowerEdge server or choose a system type by clicking on View products (e. Doesn’t matter if I boot with BIOS Oder UEFI. With CPU1 and RAM all DIMM slots filled the server boots normally. Dell EMC PowerEdge R240 PSU specifications PSU Class Heat dissipation (maximum) Frequency Voltage AC Current High line 100– 240 V Low line 100– 120 V 250 W AC Bronze 1039 BTU/hr 50/60 Hz 100-240 V AC,autoranging 250 W N/A 4. 5” Internal Solid State Drive. Overview. Dell Rewards members will earn double points on all qualifying purchases until December 3rd. 412141633 BTU/hr x (Watts) we can quickly find the BTU/hr consumption of any Cisco Meraki device. RackSolutions specifically designed fixed rails to fit the shoulder screws of the PowerEdge R420. All is working fine. I am basing my calculations of this article where in essense the formula is: Equipment BTU = Total wattage for all equipment x 3. If someone could suggest me a budget cpu upgrade that would be great :) I have bought another 64gb of Ram. Warranty upgrades are available. ⭐ Free Shipping Across Europe. Dell PowerEdge R420xr Owner's Manual Regulatory Model: E27S Series Regulatory Type: E27S001. Wait for iDRAC reboot to complete ( about 4 minutes ). x in order to be able to pull updates from Dell's website. Service Events. The console rail kit uses thePlace orders quickly and easily; View orders and track your shipping status; Create and access a list of your products; Manage your Dell EMC sites, products, and product-level contacts using Company Administration. Overview. Find replacement parts and upgrades for Your Dell system by selecting a brand or product model. Although I am showing M2, M2+, and M2R SSDs listed under both of the servers. The Dell OpenManage™ systems management portfolio includes I ntegrated Dell Remote Access Controller 7 (iDRAC7) with Lifecycle Controller. Dell PowerEdgh R420 and PERC H710 mini RAID Set-up. Dell PowerEdge R420 PowerEdge R420 • Intel Xeon E5-2400 processors • Up to eight 2. XHMDTPowerEdge Hardware General. An excellent fit for compute-intense applications and high-performance computing (HPC) workloads, the R420’s low profile also makesLCD Panel Features. (BTU/hr max) Maximum inrush current2 1356 55A 2317 55A 2133 55A 1Auto- ranging 2Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55A per power supply for 10ms or less. File Name: R420-020700C. Replacing a hot swap power supply with a left-side mounted CMA 1. Processor 2 Intel Xeon E5-2430L 2. It seems it's "v1" cpu on 1356 socket. Change product. It has one E5-2407 right now - I'm thinking of upgrading to something like an E5-2450 v2 or 2470 v2. 0. File Name: R420-020303C. Dell EMC NetShelter SX 42U Server Rack Enclosure. File Name: R420-010502C. Parts & Repairs. Recommended support Dell ProSupport Plus for critical systems or Dell ProSupport for premium hardware and software support for your PowerEdge solution. Download. A 2-socket, 1U rack server, the Dell PowerEdge R420 delivers mainstream performance and density. Expires 90 days from issuance. 1. 5-inch hot-plug hard drives • Up to 12 DIMMs with RAS • PCIe 3. Table 1. Format Description: This file format consists of a BIOS-executable file. 2021 Dell Inc. . Choose Dell ProSupport Plus for critical systems or Dell ProSupport for premium hardware and software support for your PowerEdge solution. Specs DELL PowerEdge R420 server Rack (1U) Intel® Xeon® E5 V2 Family E5-2407V2 2. Notes, Cautions, and Warnings NOTE: A NOTE indicates. If your Dell R420 isn't performing its best, the smartest and most efficient solution may be to expand its memory capacity. File Size: 3. File Name: R420-020900C. Shop Dell. Download. ^DELL BUSINESS CREDIT. 2 (20) $1,169. Dell EMC NetShelter SX 24U Server Rack Enclosure 600mm x 1070mm Half Height. Hide Table of Contents. The Dell EMC PowerEdge R330 is an excellent first server or replacement server for SMB and also highly attractive as an affordable ROBO server for large institutions. exe. in Computer Racks & Cabinets. 1 Overview The Dell™ PowerEdge™ R410 is ideal for compute-intensive applications in space-constrained environments. Format Description: This file format consists of a BIOS-executable file. 2. 4 GHz 8 GB DDR3-SDRAM 550 W R420-1649 Servers Intel Xeon E5-2407 v2 2. Used/Refurbished Dell PowerEdge MD3660i 60-Bay iSCSI Storage - Now available at Enterasource, the #1 provider of refurbished Dell storage. Parts & Repairs. Non-redundant power supply configuration. Dell PowerVault MD3660i 60-Bay 6G 10GbE iSCSI Storage Array. Find Replacement Parts & Upgrades for your PowerEdge R420 including batteries, adapters, pc accessories, memory upgrades, and more. The R420 runs quiet, cool,. 1908 BTU/hr maximum (495 W power supply) 2891 BTU/hr maximum (750 W power supply) 7 PowerEdge R320 Technical Guide Key technologies Table 1 summarizes key technologies used in the Dell PowerEdge R320 rack server. Comparison of PowerEdge systems The PowerEdge R620 is a direct replacement for the predecessor R610. $44. PowerEdge R420. Compared to the previous generation of Dell PowerEdge servers, the R620 has more drive bay options, more PCIe slots, PCIe 3. 5in Hybrid Carrier. I need 1 socket. High-performance computing Address mainstream applications with the latest Intel® Xeon® processor E5-2400 product family, designed as a foundation. The 12th generation Dell PowerEdge R420 server is ideal as a base for a data center deployment or for use in space-constrained server enclosures. temp. Dell Y8Y65 / MYG2H / P7GV4 / 9WR03 350W Redundant Hot Swappable Power Supply Unit for PowerEdge R320 R420 R420XR - Brand New. It explains how to replace a PD (physical disk or physical drive) when it is failed or in predictive failure status. Documentation. Almost all current Dell. The PowerEdge is a server line by Dell, following the naming convention for other Dell products: the PowerVault (data storage) and the PowerConnect (data transfer & switches). Back-Panel Features And Indicators. Queremos ampliar la RAM para añadir SSOO virtualizados, por lo que necesitamos un presupuesto para ampliar la RAM y, en caso necesario, añadir una segunda CPU física. 0 x16 expansion slots. Overview. Two of them blink and unblink when system starts. Second CPU PowerEdge R420. item 3 Dell JD6X3 R420 SYSTEM BOARD V3 4z Dell JD6X3 R420 SYSTEM BOARD V3 4z. A 2-socket, 1U rack server, the Dell PowerEdge R420 delivers mainstream performance and density. Respuestas(2)File Name: R420-010406C. The . Download. PowerEdge R420XR. 20 GHz 6C 64GB RAM 8x HDD. 23. So some time ago the values looked okay with 40-80 watts in usage. Dell OpenManage Enterprise. FREE & FAST DELIVERY. 4GHz CPU Kit for Dell PowerEdge R420 (Renewed) Visit the Amazon Renewed Store. Drivers & Downloads. It has a total of eight, twelve, or sixteen physical. PowerEdge R420. 0; Citrix XenServer 6. Suggested Videos. com FREE DELIVERY possible on eligible purchases Second, you should check the firmware and driver level and update if possible. Add 2 DIMMs to Slot A1, B1 (total 48GB) - passed Configuring Memory screen. Front panel. Since I bought it, it shows me weird values for the power consumption. Power AC Power Supply (per power supply) Wattage 495 W, 750 W, or 1100 W Heat dissipation NOTE: Heat dissipation is calculated using the power supply wattage rating. A 2-socket, 1U rack server, the Dell PowerEdge R420 delivers mainstream performance and density. PowerEdge R450 PSU specifications . PowerEdge R420 server. The server has 12 DIMM slots. Parts & Repairs. Take advantage of PowerEdge™ RAS features that help ensure fast, highly available service from your R420 server. 0. Not ideal for hosting the file server VMs! I have upgraded one of them to a perc H710 mini controller, a SAS cable, and 4x Dell SAS 10k hard disks. SAMSUNG 870 EVO SATA III SSD 1TB 2. Moderator. 09-09-2014 00:00 AM. Hello, I actually have a R420 server with two Intel Xeon E5-2407v1 processor (2. It is an excellent fit for compute -intense applications and high- performance computing (HPC) workloads. 168. It provides you with detailed information on the features, specifications, installation, configuration, and troubleshooting of the R720 and R720xd models. 1100 W DC NA 4265 BTU/ hr NA -48–(-60) V NA NA 1100 W 27 A 800 W Mixed Mode Platinum 3000 BTU/ hr 50/60. Let me know if you have further questions. The PowerEdge ( PE) line is Dell 's server computer product line. I know Server 2003 Standard is not supported for this server but I need to have this installed. The Dell OpenManage™ systems management portfolio includes I ntegrated Dell Remote Access Controller 7 (iDRAC7) with Lifecycle. 6. Welcome. 5in HDDs. Hi,I got an Dell PowerEdge R420 for my HomeLab. Dell R420 Stuck on Memory Configuration. Both systems feature the. It also has twelve memory slots (192GB total RAM with 16GB DIMMs), has eight 2. Dell PowerEdge R240 | This video will cover memory configuration and upgrades for the Dell PowerEdge R240 server and show you how to properly configure and i. ⭐ Free Consultation With an IT-specialist +370 5 214 1349 +370 5 214 1349File Name: R420-020402C. Server stays up but loses. Connecting The Power Cable (s) Securing The Power Cable (s) Turning On The. Documentation. Key technologies New technology Detailed description New Intel processors The new Intel Xeon processor E5-2400 and E5-2400 v2 product families, the Intel Xeon E5- PowerEdge R420. PERC S130 This new software RAID solution supports RAID 0, 1, 5 and 10 and supports a maximum of eight hot-plug SATA hard disk drives (HDD) or solid-state drives (SSD). The PowerEdge R430 chassis is 1 rack unit in height, has a depth of 27 inches and will fit in standard EIA 19 inch racks. PowerEdge R420. They are visible in PERC BIOS; I can blink and unblink them from there as well. Dell Technologies highly recommends applying this important update as soon as possible. 1U rack server, the Dell PowerEdge R420 offers. Drivers & Downloads. 895K. To use it, download the file and copy it to a DOS-bootable USB flash drive, then boot the system to the USB flash drive and run the program. 21 MB. Unpacking A Rack System. I'm planning to upgrade its CPU to get better performance for virtualization. Find compatible hardware (hard drives, memory, batteries) and accessories (speakers, headphones, keyboards, mice). Parts & Repairs. 1 Overview The PowerEdge R210 II is an entry-level, yet enterprise ready, ultra-dense 1-socket 1U rack server that is well suited for a broad range of workloads, from small businesses applications to high-density, scale-out compute farms. Installation Source Product Description. 0. I can see in the base configuration if I entered ST, it is mentioned as idrac 7 express. 00. To use it, download the file and copy it to a DOS-bootable USB flash drive, then boot the system to the USB flash drive and run the program. Format Description: This file format consists of a BIOS-executable file. This service is temporarily unavailable. Overview. Drivers & Downloads. It may only occupy a 1u space but it's densely packed and well-engineered. 1 Overview The PowerEdge R210 II is an entry-level, yet enterprise ready, ultra-dense 1-socket 1U rack server that is well suited for a broad range of workloads, from small businesses applications to high-density, scale-out compute farms. Server Dell PowerEdge R420 Installation Manual. rpm>, or to. A 2-socket, 1U rack server, the Dell PowerEdge R420 offers powerful performance and scalability. R420 - single hexcore processor 2. I've replaced the adapter and the message persists. PowerEdge R420. Expires 03/12/2023 PayPal Credit. Hi, I’m having problems setting up RAID 10 in Dell R420 with PERC H710p Mini. Documentation. Using Dell Latitude 5440 with Razer Core X Chroma eGPU with RTX4070 GPU. This video will demonstrate the replacement procedure of a Raid Card for the PowerEdge R420. Welcome to Dell. The PowerEdge R450 system supports up to two AC or DC power supply units (PSUs). 2 SSD via an PCIe adpter to on of our PowerEdge R420 servers, it started booting in UEFI mode and no longer in BIOS mode. ENERGY STAR Power and Performance Data Sheet. Documentation. iDRAC logs only show messages. BIOS; Citrix XenServer 6. Is this possible? If possible, let me know the steps and links to download and how to perform rollback in case of any failure. Server Dell PowerEdge R820 Technical Manual. It supports a maximum of two Xeon processors, up to 384GB of memory, and up to 16TB of storage. Have a PowerEdge R420 with Perc710 and the drive in bay 0 will not power up. PowerEdge Hardware General. Drivers & Downloads. 1356 BTU/hr maximum (redundant, 350 W power supply) 2132 BTU/hr maximum (redundant, 550 W power supply) 2315 BTU/hr maximum (non-redundant, 550 W power. Connecting The Power Cable (s) Securing The Power Cable (s) Turning On The System. exe. $1,625.